Sign In | Join Free | My burrillandco.com
Home > Temperature Humidity Chamber >

SUS 304# Stainless Steel Temperature And Humidity Test Chamber For Lab Use

    Buy cheap SUS 304# Stainless Steel Temperature And Humidity Test Chamber For Lab Use from wholesalers
     
    Buy cheap SUS 304# Stainless Steel Temperature And Humidity Test Chamber For Lab Use from wholesalers
    • Buy cheap SUS 304# Stainless Steel Temperature And Humidity Test Chamber For Lab Use from wholesalers
    • Buy cheap SUS 304# Stainless Steel Temperature And Humidity Test Chamber For Lab Use from wholesalers
    • Buy cheap SUS 304# Stainless Steel Temperature And Humidity Test Chamber For Lab Use from wholesalers
    • Buy cheap SUS 304# Stainless Steel Temperature And Humidity Test Chamber For Lab Use from wholesalers

    SUS 304# Stainless Steel Temperature And Humidity Test Chamber For Lab Use

    Ask Lasest Price
    Brand Name : ASLi
    Model Number : TH series
    Certification : CE
    Price : Negotiation
    Payment Terms : T/T, Western Union
    Supply Ability : 50 Set / month
    Delivery Time : 10 to 15 work days( standard model have stock)
    • Product Details
    • Company Profile

    SUS 304# Stainless Steel Temperature And Humidity Test Chamber For Lab Use

    PV solar modules testing instrument temperature and humidity

    test chamber for lab use


    Brief Introduction for PV Modules test standards


    The designed usage time for solar cell module is about 20~30years , and the reliability test is the simulation of the earth's surface photovoltaic modules (crystalline silicon and amorphous silicon thin film, concentrating) design verification, can let the module long-term operating more than 20 years in a general climate , specification requires that solar cells module do test below :


    Thermal cycle test;

    Humidity-freeze test;

    Damp Heat;


    To confirm the solar cell can withstand high temperature and high humidity level with the minus temperature influence, as well as for repeated change caused by the temperature and thermal fatigue failure, in addition to determine solar cells resistant to moisture long-term penetration ability of the test equipment design and ability to meet the relevant standards below:

    (IEC61646 , IEC61416 ,IEC61215 , UL1703 , IEC62108 , IEEE1513 ,IEC61730 etc ) .


    Related Standard

    IEC61215, IEC61646, IEC62108

    UL1703, GB9535, GB18911 Test A: Damp-heat (3000H)


    IEC61215, IEC61646, IEC62108,

    UL1703, GB9535, GB18911 Test B : Humidity-Freeze Test (400H)


    IEC61215, IEC61646, IEC62108,

    UL1703, GB9535, GB18911 Test C: Thermal Cycling (1200H)


    Silicon Solar Energy :IEC61215, UL1703 , GB9535

    Thin Film Solar Cell:IEC61646, GB18911

    Concentrating Solar Power :IEC62108 , IEEE1513


    Damp Heat :

    Condition :temperature 90 ±2 ℃ , humidity: 90% ±5% R.H.

    Testing last for 1000h ,

    P.S.: ASLi chamber can meet temperature 95 ±2 ℃ , humidity: 95% ±5% R.H.

    Purpose:To determine the ability of the module to withstand the effects of long-term penetration of humidity.


    Humidity-freeze test

    Purpose:The purpose of this test is to determine the ability of the module to withstand the effects of high temperature and humidity followed by sub-zero temperatures. This is not a thermal shock test


    Test points:low temperature -40℃,high temperature 85℃

    Max temperature rising speed rate:200℃/Hour=3.33/min

    Max temperature falling speed rate:200℃/Hour=3.33/min

    24 hours per cycle,testing for 10 cycles, 240 hours(10 days)

    Temp. Cycle CompareHigh Temp. High HumidityLow TempTemp. Change RateCycle No.
    IEC6121585℃/85±5%(20h)-40℃(0.5~4h)High Temp. Rise& Fall(100℃/h)
    Low Temp. Rise& Fall(200℃/h)
    10
    GB953585℃/85±5%(20h)-40℃(0.5~4h)High Temp. Rise& Fall(100℃/h)
    Low Temp. Rise& Fall(200℃/h)
    10
    IEC6164685℃/85±5%(20h)-40℃(0.5~4h)High Temp. Rise& Fall(100℃/h)
    Low Temp. Rise& Fall(200℃/h)
    10
    GB1891185℃/85±5%(20h)-40℃(0.5~4h)High Temp. Rise& Fall(100℃/h)
    Low Temp. Rise& Fall(200℃/h)
    10
    UL170385℃/85±2.5%(20h)-40℃(0.5~4h)High Temp. Rise& Fall(100℃/h)
    Low Temp. Rise& Fall(200℃/h)
    10
    IEC6210885℃/85±2.5%(20h)-40℃(0.5~4h)High Temp. Rise& Fall(100℃/h)
    Low Temp. Rise& Fall(200℃/h)

    20

    40


    Thermal cycle test;

    Test points:low temperature :-40℃,high temperature:85℃

    Temperature falling/rising speed rate:100℃/Hour=1.67℃/min

    6 hours per cycle, testing last 50~200 cycles

    Total testing time last 300 to 1200 hours (12.5 to 50 days )


    Temp. Cycle CompareLow TempHigh TempTemp Change Rate ℃/hDwell TimeCycle No.
    IEC61215-40±2℃85±2℃Max. 100℃/hMin.10min50, 200
    GB9535-40±2℃85±2℃Max.100℃/hMin.10min50, 200
    IEC61646-40±2℃85±2℃Max.100℃/hMin.10min50, 200
    GB18911-40±2℃85±2℃Max.100℃/hMin.10min50, 200
    UL1703-40±2℃90±2℃Max.120℃/h30~105min200
    IEC62108-40±2℃65℃,85℃,110℃10cycle/day10min500,1000,2000
    IEC62108-40℃65℃,85℃,110℃18cycle/day10min500,1000,2000
    IEEE1513-40℃90℃,110℃0.9~7.5℃/minMin.10min250,500
    IEEE1513-40℃90℃,110℃Max.100℃/hMin.10min100,200
    IEEE1513-40℃60℃,90℃Max.100℃/hMin.10min50,200